When the time comes to an end, the
sound operates and 00 flashes. The
cooking zone deactivates.
To stop the sound: touch .
Minute Minder
You can use this function as a Minute Minder when the
hob is activated and the cooking zones do not operate.
The heat setting display shows .
To activate the function: touch . Touch or
of the timer to set the time. When the time comes to an
end, the sound operates and 00 flashes.
To stop the sound: touch .
The function has no effect on the
operation of the cooking zones.
Lock
You can lock the control panel while cooking zones
operate. It prevents an accidental change of the heat
setting.
Set the heat setting first.
To activate the function: touch . comes on for 4
seconds. The Timer stays on.
To deactivate the function: touch . The previous
heat setting comes on.
When you deactivate the hob, you also
deactivate this function.
The Child Safety Device
This function prevents an accidental operation of the
hob.
To activate the function: activate the hob with . Do
not set the heat setting. Touch for 4 seconds.
comes on. Deactivate the hob with .
To deactivate the function: activate the hob with .
Do not set the heat setting. Touch for 4 seconds.
comes on. Deactivate the hob with .
To override the function for only one cooking time:
activate the hob with . comes on. Touch for 4
seconds. Set the heat setting in 10 seconds. You can
operate the hob. When you deactivate the hob with
the function operates again.
Power limitation
Originally the hob is at its highest possible power level.
To decrease or increase the power level:
1. Deactivate the hob.
2. Touch for 3 seconds. The display comes on
and goes off.
3. Touch for 3 seconds. P0 to P9 comes on.
4. Touch of front left zone to set the power level.
Power levels
Refer to “Technical information” chapter.
P0 — 7200 W
P1 — 1500 W
P2 — 2000 W
P3 — 2500 W
P4 — 3000 W
P5 — 3500 W
P6 — 4000 W
P7 — 4500 W
P8 — 5000 W
P9 — 6000 W
Caution! Make sure that the selected
power fits to the house installation fuses.
Power management function
Cooking zones are grouped according to the
location and number of the phases in the hob. See
the illustration.
Each phase has a maximum electricity loading of
3700 W.
The function divides the power between cooking
zones connected to the same phase.
The function activates when the total electricity
loading of the cooking zones connected to a single
phase exceeds 3700 W.
The function decreases the power to the other
cooking zones connected to the same phase.
The heat setting display of the reduced zones
changes between two levels.
Power management function with Power limitation
function
When you set the Power limitation function to 4.5 kW or
less, power of the hob is divided between all cooking
zones.